Top 10 Lessons From Building a Net-Zero-Energy Home
5. Little improvements add up
The lab home aimed to evaluate how effective the use of a well-sealed and integrated exterior housewrap would be toward reaching an aggressive building-envelope leakage rate of 0.60 ACH50. IBACOS tested the house when the housewrap was sealed on the exterior and integrated with the foundation and attic air barriers before any other interior air sealing or insulation measures were initiated.
To our surprise, the leakage rate was only 3.0 ACH50. Each additional air-sealing measure offered incremental improvements that made a significant difference. With the application of spray foam to strategic areas in the attic (e.g., over top plates of interior-partition walls, wiring and plumbing penetrations, and recessed light fixtures), the leakage rate was 0.88 ACH50. With spray foam in the band joists, it was 0.77 ACH50, and when the wall cavity insulation and drywall were installed, it dropped to 0.65 ACH50. After all the trim, caulking, and painting were completed, the lab home scored 0.54 ACH50, surpassing our target.
There are different approaches that can be used in different combinations, for varying degrees of cost and effort, to achieve aggressive levels of building air-tightness — and little details can have a big impact.
More like this
Comments on: "Top 10 Lessons From Building a Net-Zero-Energy Home"
Search Our Buyer's Guide
Reference Library
Professional Remodeler’s annual Market Leaders list, which identifies the top...
With demand for custom design, remodeling, and renovations at its highest level since 2005, ...
Normandy Remodeling converts confined kitchen into sprawling galley.
Each year, the National Kitchen and Bath Association surveys its members to identify the latest...
Each year, the National Kitchen and Bath Association surveys its members to identify the latest...